| 作成年度 | 2007 年度 |
|---|---|
| 論文名 | Occurrence of 17α-ethynylestradiol in wastewater in Japan |
| 論文名(和訳) | |
| 論文副題 | |
| 発表会 | SECOTOX Conference and the International Conference on Environmrntal Management, Engineering, Planning and Economics |
| 誌名 | Proceedings of SECOTOX Conference and the International Conference on Environmrntal Management, Engineering, Planning and Economics Volume Ⅱ |
| 巻・号・回 | 1 |
| 発表年月日 | 2007/06/01 |
| 所属研究室/機関名 | 著者名(英名) |
|---|---|
| 水質チーム | K.Komori, Y.Okayasu, Y.Suzuki |
| 抄録 |
|---|
| This paper describes an analytical procedure for 17α-ethynylestradiol(EE2)in domestic wastewater. The procedure demonstrated in this study is innovative in terms of levels of detection of the EE2. The detection limit of this method was 0.05 ng/L in the original sample. The field survey using this method was conducted at four wastewater treatment plants in Japan. Te results showed actual levels of influent and effluent concentrations of EE2 in sewage. The levels of EE2 measured in the influent were in the range of 0.10 to 0.32 ng/L. In the final effluent, EE2 was only detected in one wastewater sample (0.13 ng/L). It was confirmed that the reduction ratio of EE2 in wastewater treatment plants was more than 50% except one wastewater treatment plant. The behavior of EE2 in treatment plants was also studied. The concentration of EE2 decreased at every plant investigated with the progress of treatment. It was confirmed that EE2 was reduced in the process from the biological reaction tank to final settling tank. |